Get a free quote for your business

Gas detectors for propane C3H8

Learn all about propane (C3H8) and find the right gas detection system for propane monitoring.
Propane gas molecule

Propane (C3H8) and its properties

Propane (C3H8) is a flammable, colorless and odorless gas that is mainly used as a heating fuel, for cooking and in gas cylinders. It is also used in Industry and as a refrigerant. Mixed with air in high concentrations, propane can be explosive and therefore poses a hazard.

Gas detector

I2608-C3H8-P
C3H8
Propane
0 ... 100% LEL
S2157PR
C3H8
Propane
0 ... 100 % LEL
S4003PR
C3H8
Propane
0 ... 100 % LEL
I2608-C3H8-S-DM
C3H8
Propane
0 ... 100 % LEL
I2608-C3H8-S-RP33-LCD
C3H8
Propane
0 ... 100 % LEL
I2608-C3H8-S-RP33
C3H8
Propane
0 ... 100 % LEL
I2608-C3H8-S-RLCD
C3H8
Propane
0 ... 100 % LEL
I2608-C3H8-S-LCD
C3H8
Propane
0 ... 100 % LEL
I2658-C3H8-S-3G
C3H8
Propane
0 ... 100 % LEL
I2648-C3H8-S
C3H8
Propane
0 ... 100 % LEL
I2618-PR-S
C3H8
Propane
0 ... 100 % LEL
I3605-LEL-M-LCD
C3H8
Propane
0 ... 100 % LEL

Set point

Information on Set points for propane

Propane gas molecule

Set point

Lower explosion limit (LEL) 1.7 Vol. – %

  • Pre-alarm: 10% LEL (0.17 vol. – %)
  • Main alarm: 20% LEL (0.34 vol. – %)
Propane gas molecule

gas density

  • Relative Gasdichte 1.55
  • Mounting height 10 cm from floor

Gas characteristics

  • Flammable: Propane, a highly flammable gas, is used as fuel.
  • Colorless and odorless: Propane has no odor of its own, but is often mixed with a fragrance (such as ethyl mercaptan) to detect leaks.
  • Storage: As a rule, propane is stored as a liquid in pressurized containers or gas cylinders.
  • Energy source: Used as fuel in heating systems, gas barbecues and vehicles.
  • Explosion hazard: Propane can become explosive in combination with air, especially in closed rooms.

Do you require further information?

Questions about the detection of propane?

DANGERS

  • Explosion hazard: Propane can produce explosive mixtures with air. A spark or flame can cause an explosion, particularly in enclosed spaces.
  • Asphyxia (risk of suffocation): Propane can replace oxygen in high concentrations, which can cause shortness of breath or asphyxiation.
  • Fire hazard: Propane is highly flammable, which is why there is a risk of fire at any time if it escapes and comes into contact with a source of ignition.
  • Pressure vessels: Prop ane is stored at high pressure. Leaks that pose a hazard can be caused by a damaged tank or a leaking pipe.
    Propane poses a leakage hazard as it is heavier than air and can concentrate in low-lying zones. This increases the risk of abrupt ignition.

HIGH-RISK SCENARIOS

  • Indoor leakage: A propane leak inside a building can lead to a dangerous build-up of gas, increasing the risk of explosion or asphyxiation.
  • Inadequate ventilation: In areas with inadequate ventilation, propane can replace oxygen, posing a suffocation hazard to people in the vicinity.
  • Fire in the event of leaks: Leaking propane from leaking gas cylinders or pipes can catch fire immediately on contact with an ignition source and cause a fire.
  • Accident during transportation or storage: If propane containers are handled incorrectly, for example during transportation or storage, there is a risk of leaks or explosions due to depressurization.
  • Risk of explosion in the event of sparking: If the concentration of propane gas is in the right range when combined with a spark source, an explosion may occur.

Health risks and handling of propane

Concentration

KonzentrationSymptome/folgen
%gas-rep-concentration% %gas-rep-consequences%
%gas-rep-concentration% %gas-rep-consequences%
%gas-rep-concentration% %gas-rep-consequences%

Concentration table only visible in landscape format.

1. Fresh air supply:

  • Move the affected person to fresh air immediately to stop exposure to propane.

2. Keep calm:

  • Immobilize the person and ensure that they can breathe normally. Breathing problems may occur due to the displacement of oxygen.

3. Unconsciousness:

  • If the person loses consciousness, place them in the recovery position to keep their airways clear.

4. Make an emergency call:

  • Call 911 immediately to report propane poisoning and get medical help quickly.

5. No mouth-to-mouth resuscitation:

  • Do not give mouth-to-mouth resuscitation if propane has displaced the air, but wait for professional rescuers.

6. Medical treatment:

  • After receiving first aid, the affected person should be taken to hospital for further treatment.

1. Clearing:

  • Clear the affected area immediately to eliminate the risk of explosion or suffocation.

2. Ventilation:

  • Immediately ventilate the room well to dilute the propane gas and reduce the concentration.

3. Fix the leak:

  • Seal the leak if it is safe to do so and there is no danger.

4. Avoidance of ignition sources:

  • To reduce the risk of explosion, all open flames and sources of sparks should be extinguished immediately and electrical equipment switched off.

5. Make an emergency call:

  • Call 911 immediately and report the release of propane to get professional assistance quickly.

6. Use protective clothing:

  • Use appropriate protective equipment when handling propane leaks, such as respiratory protection and gloves.
Gaswarnzentrale Ultimate 5407
Discover the Gas monitors from INOSENT Gaswarntechnik AG.
Gaswarnzentrale Ultimate 5407
Discover all the information about the Ultimate 5407 Gas monitor and the associated data sheet.
Gaswarnzentrale Compact Pro
Discover all the information about the Compact Pro Gas monitors and the associated data sheet.
Discover all the information about the Cool Gate Gas monitors and the associated data sheet.
Gasmessfühler I2608
Discover the wide range of Gas detectors from INOSENT Gaswarntechnik AG.
Gasmessfühler zur Detektion von Gasen
With the I26xx series, INOSENT offers specialized solutions for application areas. Here you will find an overview of all GxxC series Gas detectors.
Interface adapter for Gas monitors

Adapter Released

Ultricies mi eget mauris pharetra et. Sagittis eu volutpat odio facilisis mauris sit amet massa.

Calibration station for mobile gas detectors

G7 Dock Bump Test Station

BLACKLINE SAFETY G7c personal safety monitor with optional

Gas monitors Ultimate

Ultimate-5307

Etiam sit amet nisl purus in mollis nunc. Nulla aliquet enim tortor at. Tincidunt vitae semper quis lectus

Mobile gas detector

Blackline G7c

Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint

Mobile gas detector

GX-6000

Libero nunc consequat interdum varius sit amet. Mauris pharetra et ultrices neque ornare aenean euism

Mobile gas detector

RP-3R-1

Ut lectus arcu bibendum at varius vel pharetra vel. Pharetra massa massa ultricies mi quis.